Research Package 1: AE31E Trino Inverted Microscope w/ Moticam ProS5 Plus and Image-Pro Life Science Fluorescence (2D) Software
Click here to get an official quote
This Research Package includes:
- AE31E LED Trinocular Inverted Microscope
- Moticam ProS5 Plus USB Camera
- Image-Pro - Life Science Fluorescence Package for Motic (2D)
- 0.65X C-Mount camera adapter
- Complete EPI-Fluorescence Attachment for AE31 ELITE
- Fluorescence Filter: DAPI/Hoechst/AlexaFluor 350
- Fluorescence Filter: EGFP/FITC/Cy2/AlexaFluor 488
- Fluorescence Filter: TRITC/Cy3/TagRFP/AlexaFluor 546
- Descriptions
- Microscope Specifications
- Camera Specifications
- Image-Pro Software Features
- Downloads
- Reviews
The AE31E Trinocular is a live cell microscope platform for advanced microbiology. The powerful LWD CCIS© Phase objectives are designed for the inspection of native cell cultures. Lab technicians save time by benefitting from a clever illumination concept. The instrument can be upgraded with Fluorescence for research tasks, while the “Light memory” function and the Auto ON/OFF mode enables a fast and safe throughput of samples.
The Hi-Sensitives - Moticam ProS5 Plus is characterized by a large 2/3' sCMOS sensor and a Global Shutter for speedy handling of moving phenomena. This camera line takes Sensitivity as a priority: Fluorescence, Polarization, and Darkfield are the applications the engineers had in mind.
Unlock the full potential of your fluorescence microscope with the Image-Pro - Life Science Fluorescence Package for Motic, developed in partnership with Media Cybernetics. This all-in-one solution allows users to capture mixed sets of fluorescence and brightfield channels, then deconvolve them using AutoQuant Real-Time Deconvolution. Combining advanced Machine Learning technology with a comprehensive suite of protocols provides precise segmentation, classification, and automated measurements from 2D fluorescence images.
This package also includes a 12-month subscription to a Standard Success Plan from Media Cybernetics, providing ongoing technical assistance and software onboarding so you can focus on the work that truly matters.
Model | AE31E Trinocular |
Observation tube | Trinocular head, Siedentopf type, 360° swiveling |
Optical system | Colour Corrected Infinity Optical System (CCIS®) |
Condenser | Focusable and centerable ELWD condenser N.A. 0.30 (WD 72mm) |
Diaphragm | Iris diaphragm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield WF10X/22mm with diopter adjustment |
Fine focus precision | 2µm |
Fluorescence | Optional HBO |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Focusing stroke | 10mm |
Free working distance | Working distance without condenser 231mm |
Illumination features | Auto-OFF and Light Memory function |
Illumination interchangeability | Quartz halogen 6V/30W or LED 3W |
Inclination | 45° inclined |
Interpupillary distance | 48-75mm |
Nosepiece | Left side facing quintuple |
Objective classification | CCIS® Plan Achromatic, DIN |
Objective mounting thread | W 4/5"x1/36" (RMS standard) |
Objectives | 4X/0.10 (WD 12.6mm), PH10X/0.25 (WD 4.1mm), LWD PH20X/0.30 (WD 4.7mm), [Optional] LWD PH40X/0.50 (WD 3.0mm) |
Phase contrast | Slider |
Stage | Plain stage with metal and glass stage inserts |
Stage size | 200x239mm |
Stand type | Inverted |
Standard contrast technique | Brightfield, phase contrast |
Transmitted illumination | Koehler Quartz halogen 6V/30W with intensity control |
Transformer | Internal |
Power supply | 100-240V (CE) |
Accessories included | Dust cover, power cord, Allen key, blue, green interference and ground glass filters, phase ring Ph1, centering telescope, centering keys, spare fuse |
Dimensions LxWxH | 556x200x529mm |
Weight Net | 11.7kg |
Model | Moticam ProS5 Plus |
Sensor type | sCMOS |
Sensor size | 2/3" |
Imaging area | 11.1mm (Diagonal) |
Capture resolution info | 5MP |
Live display mode through USB (pixels) | 2448x2048, 1224x1024 |
Pixel size | 3.45x3.45μm |
Scan mode | Progressive |
Shutter mode | Global Shutter |
Data transfer | USB 3.1 |
Max. frames per second (fps*) | 2448x2048 @ 68.3fps, 1224x1024 @ 175.8fps |
Exposure time | 7μsec to 2 sec |
Operating temperature | From -10 to +60 Degrees Celsius non condensing |
Sensitivity | 1146mV(G) @ 1/30 sec |
Support device | TWAIN, SDK and DirectShow Driver |
Supported OS | Microsoft Windows 7/8/10, MAC OSX, Linux or higher |
Minimum computer requirements | 2GHz dualcore - RAM memory 2GB - Video memory min. 512 MB |
Lens mount | C-Mount |
Software | Motic Images Plus 3.0 for Windows, OSX and Linux |
Functions | Still image and video capture, live and still image measurement, image adjustments, white balance, automatic and manual exposure, individual objective calibration system |
Power supply | 5V (from USB Port) |
Package includes | CS ring adaptor, USB 3.1 cable, Motic 4-dot calibration slide, Motic Images Plus 3.0 for Windows/OSX/Linux |
(*) Frames per second under optimal lighting conditions and in compliance with computer technical requirements. |
![]() |
Media Cybernetics: Image-Pro Fluorescence Life Science (2D) Software Image-Pro is the most advanced and innovative imaging tool available to the scientific community. Its features are specifically designed to address your imaging needs, enabling you to accurately and efficiently count objects that were previously difficult to quantify, take measurements that once posed a challenge, and uncover hidden details that would otherwise go unnoticed. |
Key Features:
-
Machine Learning-Powered Analysis
Leverage sophisticated Machine Learning algorithms for accurate segmentation and classification, ensuring automated and reliable measurements from 2D images. -
Cell Biology Protocol Collection
Optimize your research with an extensive suite of protocols for analyzing complex cell biology-based measurements, including Cell Apoptosis, Cell Autophagy, Cell Confluence, Cell Count, Cell Morphology, Cell Proliferation, Cell Transfection, Lipid Droplet, Live/Dead Cell Viability, and Ring Region. -
Multi-Channel Fluorescence Capture
Expand your imaging capabilities by capturing mixed sets of fluorescence and brightfield images. Enhance image quality using AutoQuant Real-Time Deconvolution for crisp, high-fidelity fluorescent image sets.
-
Versatility & Precision
Achieve high precision in your life science research across diverse applications with automated processes and detailed measurement capabilities.
Microscope: AE31E Trinocular
Camera: Moticam ProS5 Plus
Descriptions
The AE31E Trinocular is a live cell microscope platform for advanced microbiology. The powerful LWD CCIS© Phase objectives are designed for the inspection of native cell cultures. Lab technicians save time by benefitting from a clever illumination concept. The instrument can be upgraded with Fluorescence for research tasks, while the “Light memory” function and the Auto ON/OFF mode enables a fast and safe throughput of samples.
The Hi-Sensitives - Moticam ProS5 Plus is characterized by a large 2/3' sCMOS sensor and a Global Shutter for speedy handling of moving phenomena. This camera line takes Sensitivity as a priority: Fluorescence, Polarization, and Darkfield are the applications the engineers had in mind.
Unlock the full potential of your fluorescence microscope with the Image-Pro - Life Science Fluorescence Package for Motic, developed in partnership with Media Cybernetics. This all-in-one solution allows users to capture mixed sets of fluorescence and brightfield channels, then deconvolve them using AutoQuant Real-Time Deconvolution. Combining advanced Machine Learning technology with a comprehensive suite of protocols provides precise segmentation, classification, and automated measurements from 2D fluorescence images.
This package also includes a 12-month subscription to a Standard Success Plan from Media Cybernetics, providing ongoing technical assistance and software onboarding so you can focus on the work that truly matters.
Microscope Specifications
Model | AE31E Trinocular |
Observation tube | Trinocular head, Siedentopf type, 360° swiveling |
Optical system | Colour Corrected Infinity Optical System (CCIS®) |
Condenser | Focusable and centerable ELWD condenser N.A. 0.30 (WD 72mm) |
Diaphragm | Iris diaphragm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield WF10X/22mm with diopter adjustment |
Fine focus precision | 2µm |
Fluorescence | Optional HBO |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Focusing stroke | 10mm |
Free working distance | Working distance without condenser 231mm |
Illumination features | Auto-OFF and Light Memory function |
Illumination interchangeability | Quartz halogen 6V/30W or LED 3W |
Inclination | 45° inclined |
Interpupillary distance | 48-75mm |
Nosepiece | Left side facing quintuple |
Objective classification | CCIS® Plan Achromatic, DIN |
Objective mounting thread | W 4/5"x1/36" (RMS standard) |
Objectives | 4X/0.10 (WD 12.6mm), PH10X/0.25 (WD 4.1mm), LWD PH20X/0.30 (WD 4.7mm), [Optional] LWD PH40X/0.50 (WD 3.0mm) |
Phase contrast | Slider |
Stage | Plain stage with metal and glass stage inserts |
Stage size | 200x239mm |
Stand type | Inverted |
Standard contrast technique | Brightfield, phase contrast |
Transmitted illumination | Koehler Quartz halogen 6V/30W with intensity control |
Transformer | Internal |
Power supply | 100-240V (CE) |
Accessories included | Dust cover, power cord, Allen key, blue, green interference and ground glass filters, phase ring Ph1, centering telescope, centering keys, spare fuse |
Dimensions LxWxH | 556x200x529mm |
Weight Net | 11.7kg |
Camera Specifications
Model | Moticam ProS5 Plus |
Sensor type | sCMOS |
Sensor size | 2/3" |
Imaging area | 11.1mm (Diagonal) |
Capture resolution info | 5MP |
Live display mode through USB (pixels) | 2448x2048, 1224x1024 |
Pixel size | 3.45x3.45μm |
Scan mode | Progressive |
Shutter mode | Global Shutter |
Data transfer | USB 3.1 |
Max. frames per second (fps*) | 2448x2048 @ 68.3fps, 1224x1024 @ 175.8fps |
Exposure time | 7μsec to 2 sec |
Operating temperature | From -10 to +60 Degrees Celsius non condensing |
Sensitivity | 1146mV(G) @ 1/30 sec |
Support device | TWAIN, SDK and DirectShow Driver |
Supported OS | Microsoft Windows 7/8/10, MAC OSX, Linux or higher |
Minimum computer requirements | 2GHz dualcore - RAM memory 2GB - Video memory min. 512 MB |
Lens mount | C-Mount |
Software | Motic Images Plus 3.0 for Windows, OSX and Linux |
Functions | Still image and video capture, live and still image measurement, image adjustments, white balance, automatic and manual exposure, individual objective calibration system |
Power supply | 5V (from USB Port) |
Package includes | CS ring adaptor, USB 3.1 cable, Motic 4-dot calibration slide, Motic Images Plus 3.0 for Windows/OSX/Linux |
(*) Frames per second under optimal lighting conditions and in compliance with computer technical requirements. |
Image-Pro Software Features
![]() |
Media Cybernetics: Image-Pro Fluorescence Life Science (2D) Software Image-Pro is the most advanced and innovative imaging tool available to the scientific community. Its features are specifically designed to address your imaging needs, enabling you to accurately and efficiently count objects that were previously difficult to quantify, take measurements that once posed a challenge, and uncover hidden details that would otherwise go unnoticed. |
Key Features:
-
Machine Learning-Powered Analysis
Leverage sophisticated Machine Learning algorithms for accurate segmentation and classification, ensuring automated and reliable measurements from 2D images. -
Cell Biology Protocol Collection
Optimize your research with an extensive suite of protocols for analyzing complex cell biology-based measurements, including Cell Apoptosis, Cell Autophagy, Cell Confluence, Cell Count, Cell Morphology, Cell Proliferation, Cell Transfection, Lipid Droplet, Live/Dead Cell Viability, and Ring Region. -
Multi-Channel Fluorescence Capture
Expand your imaging capabilities by capturing mixed sets of fluorescence and brightfield images. Enhance image quality using AutoQuant Real-Time Deconvolution for crisp, high-fidelity fluorescent image sets.
-
Versatility & Precision
Achieve high precision in your life science research across diverse applications with automated processes and detailed measurement capabilities.
Downloads
Microscope: AE31E Trinocular
Camera: Moticam ProS5 Plus