Diatoms - Nature’s Jewels viewed with a Microscope
Motic America
Diatoms are unicellular algae (Division Chrysophyta, Class Bacillariophyceae). Diatoms are microscopic in size, live in water, soil and moist en...
Read ArticleDiatoms are unicellular algae (Division Chrysophyta, Class Bacillariophyceae). Diatoms are microscopic in size, live in water, soil and moist en...
Read ArticleThis Research Package includes:
*Advanced AI software is available for this package
The PA53 BIO FS6 models offer maximum flexibility for managing any kind of Fluorescence application thanks to the LUMOS High-power LED FL light source, with individual control of each LED channel. The Fluorescence filter cubes are mounted in an encoded 6-position turret: multi-color staining can easily be handled in combination with our channel-merge software plug-in. The standard configuration of PA53 BIO FS6 comes with DAPI, FITC, and TRITC filter cubes but many more can be added. Our CCIS® HPlan S-APO (High Fluorite Class) objectives provide high transmission rates for the brightest images.
The Hi-Sensitives - Moticam ProS5 Plus is characterized by a large 2/3' sCMOS sensor and a Global Shutter for speedy handling of moving phenomena. This camera line takes Sensitivity as a priority: Fluorescence, Polarization, and Darkfield are the applications the engineers had in mind.
Unlock the full potential of your fluorescence microscope with the Image-Pro ® - Life Science Fluorescence Package for Motic, developed in partnership with Media Cybernetics. This all-in-one solution allows users to capture mixed sets of fluorescence and brightfield channels, then deconvolve them using AutoQuant Real-Time Deconvolution. Combining advanced Machine Learning technology with a comprehensive suite of protocols provides precise segmentation, classification, and automated measurements from 2D fluorescence images.
This package also includes a 12-month subscription to a Standard Success Plan from Media Cybernetics, providing ongoing technical assistance and software onboarding so you can focus on the work that truly matters.
Model | PA53 BIO FS6 |
Optical System | Colour Corrected Infinity Optical System (CCIS®) |
Observation tube | Trinocular head, Siedentopf type |
Inclination | 30° inclined |
Trinocular light split | 100:0/20:80/0:100 |
Interpupillary distance | 50-75mm |
Diopter adjustment | On both eyepieces, +/- 4 diopter |
Eyepieces | Widefield WF10X/23mm with diopter adjustment |
Intermediate body | Epi-Fluorescence illuminator LUMOS LED with 6 position coded fluorescence turret and DAPI, FITC and TRITC filter cubes mounted |
Nosepiece | Reversed quintuple, coded |
Objective classification | CCIS® HPlan S-APO (Fluor) |
Objectives | • 4X/0.13 (WD 17.3mm) • 10X/0.3 (WD 11.7mm) • 20X/0.5 (WD 2.2mm) • 40X/0.75/S (WD 0.7mm) • 100X/1.3/S-Oil (WD 0.1mm) |
Objective mounting thread | W 4/5"x1/36" (RMS standard) |
Stand type | Upright |
Stage | Mechanical stage with built-in low position rackless coaxial stage control and sample holder |
Stage size | 220x170mm |
Travel range X&Y | 80x55mm |
Condenser | Focusable and centerable Abbe condenser N.A. 0.90/1.25 with slot for contrast sliders |
Diaphragm | Iris diaphragm |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Fine focus precision | 1µm |
Focusing stroke | 29.5mm - Coarse: 17.7mm/revolution - Fine: 0.1mm/revolution (1µm scale) |
Upper limit stop | Upper limit stop preset but adjustable |
Filter | ND6, ND25, LBD |
Filter holder | Integrated filters |
Incident illumination | LUMOS High-power LED FL light source (Optional: Mercury light source) |
Transmitted illumination | Köhler Quartz halogen 12V/100W with intensity control |
Illumination features | Power saving mode ECO function, LED voltage indicator and Intelligent Light function |
Software | Motic Images Plus 3.0 software with plug-in FL channel merge |
Transformer | Internal |
Power supply | 110-240V (CE) |
Accessories included | Dust cover, power cord, Allen key, immersion oil (5ml), 2 empty filter cubes, UV light blocking tube, UV light protective shield |
Dimensions LxWxH | 648x247x513mm |
Net weight | 24.2kg |
Contrast techniques | |
Standard contrast technique | Brightfield |
Phase contrast | Optional slider/turret |
Polarization | Optional add-on |
Darkfield | Optional slider/turret |
Fluorescence | LED |
Model | Moticam ProS5 Plus |
Sensor type | sCMOS |
Sensor size | 2/3" |
Imaging area | 11.1mm (Diagonal) |
Capture resolution info | 5MP |
Live display mode through USB (pixels) | 2448x2048, 1224x1024 |
Pixel size | 3.45x3.45μm |
Scan mode | Progressive |
Shutter mode | Global Shutter |
Data transfer | USB 3.1 |
Max. frames per second (fps*) | 2448x2048 @ 68.3fps, 1224x1024 @ 175.8fps |
Exposure time | 7μsec to 2 sec |
Operating temperature | From -10 to +60 Degrees Celsius non condensing |
Sensitivity | 1146mV(G) @ 1/30 sec |
Support device | TWAIN, SDK and DirectShow Driver |
Supported OS | Microsoft Windows 7/8/10, MAC OSX, Linux or higher |
Minimum computer requirements | 2GHz dualcore - RAM memory 2GB - Video memory min. 512 MB |
Lens mount | C-Mount |
Software | Motic Images Plus 3.0 for Windows, OSX and Linux |
Functions | Still image and video capture, live and still image measurement, image adjustments, white balance, automatic and manual exposure, individual objective calibration system |
Power supply | 5V (from USB Port) |
Package includes | CS ring adaptor, USB 3.1 cable, Motic 4-dot calibration slide, Motic Images Plus 3.0 for Windows/OSX/Linux |
(*) Frames per second under optimal lighting conditions and in compliance with computer technical requirements. |
![]() |
Image-Pro® Software Package by Media Cybernetics
|
Software Key Features | Standard Package | AI-Powered Package |
AI Deep Learning-Powered Analysis For superior 2D image segmentation accuracy over Machine Learning and other methods, this library of Pre-Trained AI models delivers instant segmentation results for a wide range of applications.
|
✓ | |
AI Deep Learning Model Training Fine tune the existing Pre-Trained models or build your own for custom segmentation of the most challenging images.
|
✓ | |
Machine Learning-Powered Analysis Leverage sophisticated pixel classification algorithms for accurate segmentation and classification, ensuring automated and reliable measurements from 2D images.
|
✓ | ✓ |
Analysis Protocols for guided analysis Streamline your research with a comprehensive suite of protocols designed for efficient, repeatable analysis across various life science applications—all within a simple, step-by-step workflow.
Includes: Angiogenesis, Cell Apoptosis, Autophagy, Confluence, Cell Count, Cell Morphology, Cell Proliferation, Transfection, Colocalization, Lipid Droplets, Live/Dead, Neurite Outgrowth, Nuclei, Ring Regions, Translocation, and Wound Healing. |
✓ | ✓ |
Data Visualization and Reporting Choose from 144+ measurements to display in tables and graphs, generate custom reports, and export data to Excel, CSV, or PDF. Easily share individual measurements and statistics with collaborators.
|
✓ | ✓ |
Image Processing Correct background illumination, tile and stitch large areas, colorize your images, enhance with filters, align and register images, and more. Choose from a helpful suite of options to prepare your images for analysis or publication.
|
✓ | ✓ |
Multi-Channel Fluorescence Capture Control the LUMOS LED light source with easy guided prompts to capture multiple fluorescence channels into a single multi-channel image, with Auto Exposure, and Real-Time Deconvolution.
|
✓ | ✓ |
Image Preview and Capture Designed to control the Moticam camera, you can now automatically preview a live image and effortlessly capture LIVE Tiling, LIVE EDF, LIVE HDR, Timelapse movies, and beautiful still images.
|
✓ | ✓ |
Check compatibility with Image-Pro
Different packages have varying system requirements. Check your computer’s specifications against the system requirements for Image-Pro software. | See System Requirements |
Microscope: PA53 BIO FS6
Camera: Moticam ProS5 Plus
Install app