The BA410E Phase package comes with a turret condenser and other phase equipment allowing users to view their samples using phase contrast.
The BA410E is Motic's flagship model, and it displays the highest level of optical performance. With a complete set of EC-H Plan Apochromatic lenses, it allows maximum clarity in color reproduction and resolution. The BA410E also allows a profound diagnosis for those in pathology, hematology, and cytology who require the best color fidelity. Increased numerical apertures provide an expanded resolution power for a more detailed specimen evaluation.
Note: The BA410E is a custom order item.
- Specifications
- Downloads
- Videos
- Reviews
Model | BA410E Trinocular Sextuple 50W |
Observation tube | Trinocular head, Siedentopf type |
Optical system | Colour Corrected Infinity Optical System (CCIS®) |
Condenser | Focusable and centerable Swing-out Abbe condenser N.A. 0.90/0.13 |
Darkfield | Iris diaphragm |
Data transfer | Optional slider/turret |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/22mm with diopter adjustment |
Filter holder | On top of the illuminator with fixing cap |
Fine focus precision | 1µm |
Fluorescence | Optional HBO |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Focusing stroke | 27mm |
Illumination features | Auto-OFF and Light Memory function. External lamphouse. |
Illumination interchangeability | Quartz halogen 12V/50W or LED 3W |
Inclination | 30° inclined, 360° rotating |
Interpupillary distance | 50-75mm |
Nosepiece | Reversed sextuple |
Objective classification | CCIS® EC-H Plan Achromatic, DIN |
Objective mounting thread | W 4/5"x1/36" (RMS standard) |
Objectives | 4X/0.10 (WD 15.9mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.5mm), 100X/1.25/S-Oil (WD 0.15mm) |
Phase contrast | Optional slider/turret |
Polarization | Optional sliders/add on |
Stage | Mechanical stage with built-in low position rackless coaxial stage control, ceramic insert and sample holder |
Stage size | 180x170mm |
Stand type | Upright |
Standard contrast technique | Brightfield |
Transmitted illumination | Koehler Quartz halogen 12V/50W with intensity control |
Travel range X&Y | 80x55mm |
Trinocular light split | 100:0/20:80 (optional 100:0/0:100 or 100:0/0:100/20:80) |
Upper limit stop | Upper limit stop preset but adjustable |
Transformer | Internal |
Power supply | 100-240V (CE) |
Accessories included | Dust cover, power cord, Allen key, immersion oil (5ml), blue filter, spare fuse, arm rest |
Dimensions LxWxH | 550x242x435mm |
Weight Net | 14.2kg |
Contrast Methods - Polarization Contrast in BA410E
Discover how to setup the polarizing equipment in our BA410E upright microscope.
Contrast Methods - Polarizing system
Discover how to use the polarization contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Simple Phase Contrast
Discover how to use the Phase Contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Turret Phase Contrast
Discover how to perform the Phase Contrast method with the Turret Condenser solution, in our upright microscopes BA310, BA410 and its Elite versions.
Contrast Methods - Darkfield with turret solution for BA310, BA310E & BA410E
Discover how to perform the darkfield contrast method with the turret solution, in our BA series of upright microscopes BA310, BA310E and BA410E models.
Contrast Methods - Darkfield with slider solution for BA series
Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions.
Contrast Methods - HBO lamphouse set-up and alignment for BA410E & AE31E
Learn how to set-up and align the Fluorescence HBO lamphouse for the BA410E & AE31E upright and inverted microscopes.
Koehler Illumination - Setup & Alignment
Know how to use the Koehler illumination properly in the BA310, BA310E, BA410 and BA410E Series.
Contrast Methods - How to setup the fluorescence attachment on a BA410E
Discover how to setup the fluorescence attachment in our BA410E upright microscope.
Motic Lumos Fluorescence LED illuminator - Making visible the invisible
Discover our most advanced fluorescence LED illuminator, which integrates seamlessly with our PA53 BIO series, BA410E, and AE31E microscopes to produce dazzling images of fluorochrome-labelled specimens.
How to change the halogen bulb & LED module of a BA410E
Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA410E microscope.
How to adjust the tension of the focusing system (ring). E.g. AE Series
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope.
How to adjust the microscope illumination
If you are wondering how to get good, clear and crisp images from your microscope, the key point is ensuring that your sample is correctly illuminated. In this video, we will show you in just a few steps, how to adjust the illumination of your microscope to get the best image out of your device.
How to do the parfocality adjustment on an upright microscope
Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.
How to avoid repairs in your microscope
Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.
How to mount the reticle into the eyepiece
Learn how easy it is to mount a reticle into the eyepiece of your Motic microscope.
Downloads
Videos
Contrast Methods - Polarization Contrast in BA410E
Discover how to setup the polarizing equipment in our BA410E upright microscope.
Contrast Methods - Polarizing system
Discover how to use the polarization contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Simple Phase Contrast
Discover how to use the Phase Contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Turret Phase Contrast
Discover how to perform the Phase Contrast method with the Turret Condenser solution, in our upright microscopes BA310, BA410 and its Elite versions.
Contrast Methods - Darkfield with turret solution for BA310, BA310E & BA410E
Discover how to perform the darkfield contrast method with the turret solution, in our BA series of upright microscopes BA310, BA310E and BA410E models.
Contrast Methods - Darkfield with slider solution for BA series
Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions.
Contrast Methods - HBO lamphouse set-up and alignment for BA410E & AE31E
Learn how to set-up and align the Fluorescence HBO lamphouse for the BA410E & AE31E upright and inverted microscopes.
Koehler Illumination - Setup & Alignment
Know how to use the Koehler illumination properly in the BA310, BA310E, BA410 and BA410E Series.
Contrast Methods - How to setup the fluorescence attachment on a BA410E
Discover how to setup the fluorescence attachment in our BA410E upright microscope.
Motic Lumos Fluorescence LED illuminator - Making visible the invisible
Discover our most advanced fluorescence LED illuminator, which integrates seamlessly with our PA53 BIO series, BA410E, and AE31E microscopes to produce dazzling images of fluorochrome-labelled specimens.
How to change the halogen bulb & LED module of a BA410E
Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA410E microscope.
How to adjust the tension of the focusing system (ring). E.g. AE Series
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope.
How to adjust the microscope illumination
If you are wondering how to get good, clear and crisp images from your microscope, the key point is ensuring that your sample is correctly illuminated. In this video, we will show you in just a few steps, how to adjust the illumination of your microscope to get the best image out of your device.
How to do the parfocality adjustment on an upright microscope
Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.
How to avoid repairs in your microscope
Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.
How to mount the reticle into the eyepiece
Learn how easy it is to mount a reticle into the eyepiece of your Motic microscope.