The Starting Point.

The Moticam S1 as the entry model for back-illuminated sensor technology and speedy data transfer (excellent frame rates up to 120 fps) creates an optimal imaging environment and makes capturing images easy. Create your perfect images for a professional database.

The right choice for challenging tasks in professional fields. The Moticam S Series offers smooth navigation, high colour fidelity, and crisp images designed by German engineers. Time efficiency in its best resolution from HD up to QHD+.

• The Speedy Standards
Moticam S1 and Moticam S3 are designed for the fast and accurate imaging of results in biomedical environments or industry. Ultra-fast image capture and smooth navigation through your samples in live mode. Excellent balance of speed and image quality.

• The Hi-Res Experts
Moticam S6, Moticam S12 and Moticam S20 are focused on resolution, ready to reveal the tiniest detail of your sample on a large screen. Documentation in printed format is no problem at all. The data volume created by the 6/12/20MP sensors should be handled by a computer with USB 3.1 Gen.1 port for faster transmission.

• The Hi-Sensitives
Moticam Pro S5 Lite and Moticam Pro S5 Plus are characterized by a large 2/3' sCMOS sensor and a Global Shutter for speedy handling of moving phenomena. This camera line takes Sensitivity as a priority: Fluorescence, Polarization, and Darkfield are the applications the engineers had in mind.

Model S1 S3 S6 S12 S20 Pro S5 Lite Pro S5 Plus
Sensor Type

sCMOS

Sensor Size 1/3" 1/2.8" 1/1.8" 1/1.7" 1" 2/3" 2/3"
Imaging Area 6.09mm (Diagonal) 6.44mm (Diagonal) 8.92mm (Diagonal) 9.33mm (Diagonal) 15.86mm (Diagonal) 11.1mm (Diagonal) 11.1mm (Diagonal)
Capture Resolution Info 1.2MP 3MP 6MP 12Mp 20MP 5MP 5MP
Live display mode through USB (pixels) 1280x960, 640x480 2048x1536, 1920x1080 3072x2048, 1536x1024 4000x3000, 2048x1080 5472x3648, 2736x1824 2448x2048, 1224x1024 2448x2048, 1224x1024
Pixel size 3.75x3.75μm 2.5x2.5μm 2.4x2.4μm 1.85x1.85μm 2.4x2.4μm 3.45x3.45μm 3.45x3.45μm
Scan mode

Progressive

Shutter mode Rolling Shutter  Rolling Shutter Rolling Shutter Rolling Shutter  Rolling Shutter Global Shutter Global Shutter
Data transfer

USB 3.1

Max. frames per second (fps*) 1280x960 @ 120fps, 640x480 @ 240fps 2048x1536 @ 60fps, 1920x1080 @ 60fps 3072x2048 @ 30fps, 1536x1024 @ 50fps 4000x3000 @ 25fps, 2048x1080 @ 50fps 5472x3648 @ 18fps, 2736x1824 @ 50fps 2448x2048 @ 37.5fps, 1224x1024 @ 88.4fps 2448x2048 @ 68.3fps, 1224x1024 @ 175.8fps
Exposure time 15 μsec to 2 sec 21 μsec to 2 sec 16 μsec to 2 sec 22 μsec to 2 sec 15 μsec to 2 sec 14 μsec to 2 sec 7 μsec to 2 sec
Operating temperature

From -10 to +60 Degrees Celsius non condensing

Sensitivity 2350mV(G) @ 1/30 sec 600mV(G) @ 1/30 sec 425mV(G) @ 1/30 sec 280mV(G) @ 1/30 sec 461mV(G) @ 1/30 sec 1146mV(G) @ 1/30 sec 1146mV(G) @ 1/30 sec
Support device

TWAIN, SDK and DirectShow Driver

Supported OS

Microsoft Windows 7/8/10, MAC OSX, Linux or higher

Minimum computer requirements

2GHz dualcore - RAM memory 2GB - Video memory min. 512 MB

Lens mount

C-Mount

Software

Motic Images Plus 3.0 for Windows, OSX and Linux

Functions

Still image and video capture, live and still image measurement, image adjustments, white balance, automatic & manual exposure, individual objective calibration system

Power supply

5V (from USB Port)

Package includes

CS ring adaptor, USB 3.1 cable, Motic 4-dot calibration slide, Motic Images Plus 3.0 for Windows/OSX/Linux

(*) Frames per second under optimal lighting conditions and in compliance with computer technical requirements.

Moticam S Series Launch

Have an overview of the complete Moticam S Series and start your digital voyage with our new camera generation. The accelerated data readout enables to work on fast phenomena in biology, industry, polarization or fluorescence. Sensitivity, speed and sensor size no limits.

How to connect your Moticam onto the eyepiece

Learn how to connect your Moticam onto the eyepiece easily.

How to connect your Moticam onto the trinocular tube

Learn how to connect your Moticam onto the trinocular tube easily.

New Motic Images Plus 3.0 Launch

A small taste of the Motic Images Plus 3.0 software.

Motic Images Plus 3.0 & 3.1 - First Steps tutorial

Learn how to make your first steps with Motic Images Plus 3.0 software. From software installation up to making professional measurements, we guide you step by step through getting a great live image, applying image adjustments to see the microscope's image as wished or the most closely to eyepiece observation, and capturing an image or video. All you might need to start with confidence.

Motic Images Plus 3.0 & 3.1 - Calibration tutorial

Calibration simply explained: Learn how to calibrate Motic Image Plus 3.0 software, a must in professional environments where exact scale and measurements are a daily need. Easy to follow step-by-step explanation with tips & tricks to perform it accurately.

At Motic Instruments, we take pride in the quality of our products and our user experience. That's why we offer technical advice and full post-sale support to keep your Motic products in optimal condition and ensure your microscopy results are of the highest quality. All of our microscopes are covered by a 5 year warranty on mechanical components and 1 year warranty on electrical components. 

All returns must be authorized by Motic Instruments in order to insure proper credit and must be requested within 15 days of purchase. All returns may be subject to a 25% restocking charge and any cancellations may be subject to a cancellation fee. For returns not due to Motic error, the customer is responsible for all transportation fees related to the returned product. Should a return be granted, the purchase amount less shipping & handling fee and other applicable fees (restocking charge) will be deducted.

Descriptions

The right choice for challenging tasks in professional fields. The Moticam S Series offers smooth navigation, high colour fidelity, and crisp images designed by German engineers. Time efficiency in its best resolution from HD up to QHD+.

• The Speedy Standards
Moticam S1 and Moticam S3 are designed for the fast and accurate imaging of results in biomedical environments or industry. Ultra-fast image capture and smooth navigation through your samples in live mode. Excellent balance of speed and image quality.

• The Hi-Res Experts
Moticam S6, Moticam S12 and Moticam S20 are focused on resolution, ready to reveal the tiniest detail of your sample on a large screen. Documentation in printed format is no problem at all. The data volume created by the 6/12/20MP sensors should be handled by a computer with USB 3.1 Gen.1 port for faster transmission.

• The Hi-Sensitives
Moticam Pro S5 Lite and Moticam Pro S5 Plus are characterized by a large 2/3' sCMOS sensor and a Global Shutter for speedy handling of moving phenomena. This camera line takes Sensitivity as a priority: Fluorescence, Polarization, and Darkfield are the applications the engineers had in mind.

Specifications

Model S1 S3 S6 S12 S20 Pro S5 Lite Pro S5 Plus
Sensor Type

sCMOS

Sensor Size 1/3" 1/2.8" 1/1.8" 1/1.7" 1" 2/3" 2/3"
Imaging Area 6.09mm (Diagonal) 6.44mm (Diagonal) 8.92mm (Diagonal) 9.33mm (Diagonal) 15.86mm (Diagonal) 11.1mm (Diagonal) 11.1mm (Diagonal)
Capture Resolution Info 1.2MP 3MP 6MP 12Mp 20MP 5MP 5MP
Live display mode through USB (pixels) 1280x960, 640x480 2048x1536, 1920x1080 3072x2048, 1536x1024 4000x3000, 2048x1080 5472x3648, 2736x1824 2448x2048, 1224x1024 2448x2048, 1224x1024
Pixel size 3.75x3.75μm 2.5x2.5μm 2.4x2.4μm 1.85x1.85μm 2.4x2.4μm 3.45x3.45μm 3.45x3.45μm
Scan mode

Progressive

Shutter mode Rolling Shutter  Rolling Shutter Rolling Shutter Rolling Shutter  Rolling Shutter Global Shutter Global Shutter
Data transfer

USB 3.1

Max. frames per second (fps*) 1280x960 @ 120fps, 640x480 @ 240fps 2048x1536 @ 60fps, 1920x1080 @ 60fps 3072x2048 @ 30fps, 1536x1024 @ 50fps 4000x3000 @ 25fps, 2048x1080 @ 50fps 5472x3648 @ 18fps, 2736x1824 @ 50fps 2448x2048 @ 37.5fps, 1224x1024 @ 88.4fps 2448x2048 @ 68.3fps, 1224x1024 @ 175.8fps
Exposure time 15 μsec to 2 sec 21 μsec to 2 sec 16 μsec to 2 sec 22 μsec to 2 sec 15 μsec to 2 sec 14 μsec to 2 sec 7 μsec to 2 sec
Operating temperature

From -10 to +60 Degrees Celsius non condensing

Sensitivity 2350mV(G) @ 1/30 sec 600mV(G) @ 1/30 sec 425mV(G) @ 1/30 sec 280mV(G) @ 1/30 sec 461mV(G) @ 1/30 sec 1146mV(G) @ 1/30 sec 1146mV(G) @ 1/30 sec
Support device

TWAIN, SDK and DirectShow Driver

Supported OS

Microsoft Windows 7/8/10, MAC OSX, Linux or higher

Minimum computer requirements

2GHz dualcore - RAM memory 2GB - Video memory min. 512 MB

Lens mount

C-Mount

Software

Motic Images Plus 3.0 for Windows, OSX and Linux

Functions

Still image and video capture, live and still image measurement, image adjustments, white balance, automatic & manual exposure, individual objective calibration system

Power supply

5V (from USB Port)

Package includes

CS ring adaptor, USB 3.1 cable, Motic 4-dot calibration slide, Motic Images Plus 3.0 for Windows/OSX/Linux

(*) Frames per second under optimal lighting conditions and in compliance with computer technical requirements.

Downloads

Videos

Moticam S Series Launch

Have an overview of the complete Moticam S Series and start your digital voyage with our new camera generation. The accelerated data readout enables to work on fast phenomena in biology, industry, polarization or fluorescence. Sensitivity, speed and sensor size no limits.

How to connect your Moticam onto the eyepiece

Learn how to connect your Moticam onto the eyepiece easily.

How to connect your Moticam onto the trinocular tube

Learn how to connect your Moticam onto the trinocular tube easily.

New Motic Images Plus 3.0 Launch

A small taste of the Motic Images Plus 3.0 software.

Motic Images Plus 3.0 & 3.1 - First Steps tutorial

Learn how to make your first steps with Motic Images Plus 3.0 software. From software installation up to making professional measurements, we guide you step by step through getting a great live image, applying image adjustments to see the microscope's image as wished or the most closely to eyepiece observation, and capturing an image or video. All you might need to start with confidence.

Motic Images Plus 3.0 & 3.1 - Calibration tutorial

Calibration simply explained: Learn how to calibrate Motic Image Plus 3.0 software, a must in professional environments where exact scale and measurements are a daily need. Easy to follow step-by-step explanation with tips & tricks to perform it accurately.

Warranty

At Motic Instruments, we take pride in the quality of our products and our user experience. That's why we offer technical advice and full post-sale support to keep your Motic products in optimal condition and ensure your microscopy results are of the highest quality. All of our microscopes are covered by a 5 year warranty on mechanical components and 1 year warranty on electrical components. 

Return Policy

All returns must be authorized by Motic Instruments in order to insure proper credit and must be requested within 15 days of purchase. All returns may be subject to a 25% restocking charge and any cancellations may be subject to a cancellation fee. For returns not due to Motic error, the customer is responsible for all transportation fees related to the returned product. Should a return be granted, the purchase amount less shipping & handling fee and other applicable fees (restocking charge) will be deducted.