Panthera E2 + Moticam A16 Bundle
$2,664
Click here to get an official quote
This limited time bundle special comes with:
- Panthera E2 Trinocular
- Moticam A16
- Compatible C-mount adapter
Ideal for education use, the Panthera E2 has a rackless stage and a 360º rotatable head specially for space-saving storage. It has Plan UC optics and an extremely efficient low power illumination, allowing it to run on a mobile battery pack for several hours. The Panthera E2 is able to perform phase contrast and darkfield.
- Panthera E2 Specifications
- Moticam A16 Specifications
- Downloads
- Videos
- Reviews
Model | Panthera E2 Trinocular |
Observation tube | Trinocular head, Siedentopf type, 360° swiveling |
Optical system | Colour Corrected Infinity Optical System (CCIS®) |
Condenser | Focusable and centerable Abbe condenser N.A. 0.90/1.25 with slot for contrast sliders |
Darkfield | Optional slider |
Diaphragm | Iris diaphragm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/20mm with diopter adjustment |
Filter holder | On top of the illuminator |
Fine focus precision | 2µm |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Focusing stroke | 25mm |
Illumination features | Nosepiece LED light intensity indicator |
Inclination | 25° inclined, 360° rotating (storage saving), 360° swivelling |
Interpupillary distance | 48-75mm |
Nosepiece | Reversed quadruple |
Objective classification | CCIS® SC Plan Achromatic, DIN |
Objective mounting thread | W 4/5"x1/36" (RMS standard) |
Objectives | 4X/0.10 (WD 15.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 100X/1.25/S-Oil (WD 0.14mm) |
Other features | USB 2.0 for external camera power |
Phase contrast | Optional slider |
Polarization | Optional add-on |
Stage | Mechanical stage with built-in low position rackless coaxial stage control and sample holder |
Stage size | 140x135mm |
Stand type | Upright |
Standard contrast technique | Brightfield |
Transmitted illumination | Fixed Koehler LED 1W with intensity control |
Travel range X&Y | 75x40mm |
Upper limit stop | Upper limit stop preset but adjustable |
Transformer | Internal |
Power supply | 110-240V (CE), USB 2.0 for battery pack |
Accessories included | Dust cover, power cord, Allen key, immersion oil (5ml) |
Dimensions LxWxH | 282x210x396mm |
Weight Net | 7.5kg |
Camera | A16 |
Sensor Type |
sCMOS |
Sensor Size |
1 / 2.3" |
Capture Resolution |
16MP |
Live Display Modes |
4608x3456, 3263x2448, 1920x1080 |
Pixel Size |
1.4x1.34 micron |
Max. FPS |
15fps @ 4608x3456, 30fps @ 1920x1080 |
Lens Mount |
C-Mount |
Additional Support |
TWAIN, SDK, DS Driver |
Operating System |
Windows 10 or higher, OSX10.9 or higher |
Software |
MotiConnect available for free download. Free Updates included |
Included Accessories |
Focusable Lens, 30mm & 38mm Eyepiece Adapters, Calibration Slide, Macro Viewing Tube, C-Ring, USB Cable, Dust Cap |
Panthera Generation 2 Launch
Discover the 2nd Generation of PANTHERA. Developed for those with sophisticated quality thinking. The right choice is now much simpler to find in the jungle of performance awards and crowded market of solutions. New Panthera E2 and Panthera C2 microscopes...Lift-up your performance to a world-class level!
Panthera Compound Microscopes Series
Have an overview of the complete Panthera Series, our brand new upright microscopes range covering from the educational field, going through advanced models for clinics and labs and up to industrial and material sciences applications.
Panthera Microscope Series: Unleash your Potentials
The recent Panthera upright microscope Series is in constant evolution, ready to cover your demands and fit in every application field. A smart and versatile microscope line ready to optimize your daily workflow.
How to do the parfocality adjustment on an upright microscope
Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.
How to adjust the microscope illumination
If you are wondering how to get good, clear and crisp images from your microscope, the key point is ensuring that your sample is correctly illuminated. In this video, we will show you in just a few steps, how to adjust the illumination of your microscope to get the best image out of your device.
How to avoid repairs in your microscope
Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.
Panthera E2 Specifications
Model | Panthera E2 Trinocular |
Observation tube | Trinocular head, Siedentopf type, 360° swiveling |
Optical system | Colour Corrected Infinity Optical System (CCIS®) |
Condenser | Focusable and centerable Abbe condenser N.A. 0.90/1.25 with slot for contrast sliders |
Darkfield | Optional slider |
Diaphragm | Iris diaphragm |
Diopter adjustment | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/20mm with diopter adjustment |
Filter holder | On top of the illuminator |
Fine focus precision | 2µm |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment |
Focusing stroke | 25mm |
Illumination features | Nosepiece LED light intensity indicator |
Inclination | 25° inclined, 360° rotating (storage saving), 360° swivelling |
Interpupillary distance | 48-75mm |
Nosepiece | Reversed quadruple |
Objective classification | CCIS® SC Plan Achromatic, DIN |
Objective mounting thread | W 4/5"x1/36" (RMS standard) |
Objectives | 4X/0.10 (WD 15.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 100X/1.25/S-Oil (WD 0.14mm) |
Other features | USB 2.0 for external camera power |
Phase contrast | Optional slider |
Polarization | Optional add-on |
Stage | Mechanical stage with built-in low position rackless coaxial stage control and sample holder |
Stage size | 140x135mm |
Stand type | Upright |
Standard contrast technique | Brightfield |
Transmitted illumination | Fixed Koehler LED 1W with intensity control |
Travel range X&Y | 75x40mm |
Upper limit stop | Upper limit stop preset but adjustable |
Transformer | Internal |
Power supply | 110-240V (CE), USB 2.0 for battery pack |
Accessories included | Dust cover, power cord, Allen key, immersion oil (5ml) |
Dimensions LxWxH | 282x210x396mm |
Weight Net | 7.5kg |
Moticam A16 Specifications
Camera | A16 |
Sensor Type |
sCMOS |
Sensor Size |
1 / 2.3" |
Capture Resolution |
16MP |
Live Display Modes |
4608x3456, 3263x2448, 1920x1080 |
Pixel Size |
1.4x1.34 micron |
Max. FPS |
15fps @ 4608x3456, 30fps @ 1920x1080 |
Lens Mount |
C-Mount |
Additional Support |
TWAIN, SDK, DS Driver |
Operating System |
Windows 10 or higher, OSX10.9 or higher |
Software |
MotiConnect available for free download. Free Updates included |
Included Accessories |
Focusable Lens, 30mm & 38mm Eyepiece Adapters, Calibration Slide, Macro Viewing Tube, C-Ring, USB Cable, Dust Cap |
Downloads
Videos
Panthera Generation 2 Launch
Discover the 2nd Generation of PANTHERA. Developed for those with sophisticated quality thinking. The right choice is now much simpler to find in the jungle of performance awards and crowded market of solutions. New Panthera E2 and Panthera C2 microscopes...Lift-up your performance to a world-class level!
Panthera Compound Microscopes Series
Have an overview of the complete Panthera Series, our brand new upright microscopes range covering from the educational field, going through advanced models for clinics and labs and up to industrial and material sciences applications.
Panthera Microscope Series: Unleash your Potentials
The recent Panthera upright microscope Series is in constant evolution, ready to cover your demands and fit in every application field. A smart and versatile microscope line ready to optimize your daily workflow.
How to do the parfocality adjustment on an upright microscope
Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.
How to adjust the microscope illumination
If you are wondering how to get good, clear and crisp images from your microscope, the key point is ensuring that your sample is correctly illuminated. In this video, we will show you in just a few steps, how to adjust the illumination of your microscope to get the best image out of your device.
How to avoid repairs in your microscope
Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.