BA210E
Binocular LED (5000K)
$1,299
A compound microscope perfect for basic work in life sciences, education, and industrial environments. The use of Motic's Plan Achromatic objectives ensures the clarity and precision of sections, smears, and native transparent samples. Students and lab technicians benefit from the pre-installed optics and illuminations.
- Specifications
- Downloads
- Videos
- Warranty
- Return Policy
- Reviews
Model | BA210E Binocular | BA210E Trinocular |
Observation tube | Binocular head, Siedentopf type | Trinocular head, Siedentopf type |
Optical system | Colour Corrected Infinity Optical System (CCIS®) | Colour Corrected Infinity Optical System (CCIS®) |
Condenser | Focusable Abbe condenser N.A. 1.25 with slot for contrast sliders | Focusable Abbe condenser N.A. 1.25 with slot for contrast sliders |
Darkfield | Optional slider | Optional slider |
Diaphragm | Iris diaphragm | Iris diaphragm |
Diopter adjustment | On both eyepieces, +/- 5 diopter | On both eyepieces, +/- 5 diopter |
Eyepieces | Widefield N-WF10X/20mm with diopter adjustment | Widefield N-WF10X/20mm with diopter adjustment |
Filter holder | On top of the illuminator with fixing cap | On top of the illuminator with fixing cap |
Fine focus precision | 2µm | 2µm |
Fluorescence | Optional LED | Optional LED |
Focus mechanism | Coaxial coarse and fine focusing system with tension adjustment | Coaxial coarse and fine focusing system with tension adjustment |
Focusing stroke | 20mm | 20mm |
Illumination interchangeability | Quartz halogen 6V/30W or LED 3W | Quartz halogen 6V/30W or LED 3W |
Inclination | 30° inclined, 360° rotating | 30° inclined, 360° rotating |
Interpupillary distance | 55-75mm | 55-75mm |
Nosepiece | Reversed quadruple | Reversed quadruple |
Objective classification | CCIS® EC Plan Achromatic, DIN | CCIS® EC Plan Achromatic, DIN |
Objective mounting thread | W 4/5"x1/36" (RMS standard) | W 4/5"x1/36" (RMS standard) |
Objectives | 4X/0.10 (WD 15.9mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.5mm), 100X/1.25/S-Oil (WD 0.15mm) | 4X/0.10 (WD 15.9mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.5mm), 100X/1.25/S-Oil (WD 0.15mm) |
Phase contrast | Optional slider | Optional slider |
Polarization | Optional add-on | Optional add-on |
Stage | Mechanical stage with built-in low position rackless coaxial stage control and sample holder | Mechanical stage with built-in low position rackless coaxial stage control and sample holder |
Stage size | 150x150mm | 150x150mm |
Stand type | Upright | Upright |
Standard contrast technique | Brightfield | Brightfield |
Transmitted illumination | Quartz halogen 6V/30W with intensity control | Quartz halogen 6V/30W with intensity control |
Travel range X&Y | 80x30mm | 80x30mm |
Upper limit stop | Upper limit stop preset but adjustable | Upper limit stop preset but adjustable |
Transformer | Internal | Internal |
Power supply | 100-240V (CE) | 100-240V (CE) |
Accessories included | Dust cover, power cord, Allen key, immersion oil (5ml), blue filter, spare fuse, cord hanger, thumb screw | Dust cover, power cord, Allen key, immersion oil (5ml), blue filter, spare fuse, cord hanger, thumb screw |
Dimensions LxWxH | 360x220x395mm | 360x220x395mm |
Weight Net | 7.2kg | 7.2kg |
Contrast Methods - Polarization Contrast in BA210, BA210E, BA310 & BA310E
Discover how to setup the polarizing equipment in our BA210 and BA310 upright microscopes, and its Elite versions.
Contrast Methods - Polarizing system
Discover how to use the polarization contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Simple Phase Contrast
Discover how to use the Phase Contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Darkfield with slider solution for BA series
Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions.
How to change the halogen bulb & LED module of a BA210, BA310, BA210E and BA310E
Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA210, BA310, BA210E and BA310E microscopes.
How to adjust the tension of the focusing system (ring). E.g. AE Series
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope.
How to adjust the microscope illumination
If you are wondering how to get good, clear and crisp images from your microscope, the key point is ensuring that your sample is correctly illuminated. In this video, we will show you in just a few steps, how to adjust the illumination of your microscope to get the best image out of your device.
How to do the parfocality adjustment on an upright microscope
Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.
How to avoid repairs in your microscope
Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.
How to mount the reticle into the eyepiece
Learn how easy it is to mount a reticle into the eyepiece of your Motic microscope.
At Motic Instruments, we take pride in the quality of our products and our user experience. That's why we offer technical advice and full post-sale support to keep your Motic products in optimal condition and ensure your microscopy results are of the highest quality. All of our microscopes are covered by a 5 year warranty on mechanical components and 1 year warranty on electrical components.
All returns must be authorized by Motic Instruments in order to insure proper credit and must be requested within 15 days of purchase. All returns may be subject to a 25% restocking charge and any cancellations may be subject to a cancellation fee. For returns not due to Motic error, the customer is responsible for all transportation fees related to the returned product. Should a return be granted, the purchase amount less shipping & handling fee and other applicable fees (restocking charge) will be deducted.
Downloads
Videos
Contrast Methods - Polarization Contrast in BA210, BA210E, BA310 & BA310E
Discover how to setup the polarizing equipment in our BA210 and BA310 upright microscopes, and its Elite versions.
Contrast Methods - Polarizing system
Discover how to use the polarization contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Simple Phase Contrast
Discover how to use the Phase Contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.
Contrast Methods - Darkfield with slider solution for BA series
Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions.
How to change the halogen bulb & LED module of a BA210, BA310, BA210E and BA310E
Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA210, BA310, BA210E and BA310E microscopes.
How to adjust the tension of the focusing system (ring). E.g. AE Series
Learn how easy it is to adjust the tension of the focusing system of your Motic microscope.
How to adjust the microscope illumination
If you are wondering how to get good, clear and crisp images from your microscope, the key point is ensuring that your sample is correctly illuminated. In this video, we will show you in just a few steps, how to adjust the illumination of your microscope to get the best image out of your device.
How to do the parfocality adjustment on an upright microscope
Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.
How to avoid repairs in your microscope
Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.
How to mount the reticle into the eyepiece
Learn how easy it is to mount a reticle into the eyepiece of your Motic microscope.
Warranty
At Motic Instruments, we take pride in the quality of our products and our user experience. That's why we offer technical advice and full post-sale support to keep your Motic products in optimal condition and ensure your microscopy results are of the highest quality. All of our microscopes are covered by a 5 year warranty on mechanical components and 1 year warranty on electrical components.
Return Policy
All returns must be authorized by Motic Instruments in order to insure proper credit and must be requested within 15 days of purchase. All returns may be subject to a 25% restocking charge and any cancellations may be subject to a cancellation fee. For returns not due to Motic error, the customer is responsible for all transportation fees related to the returned product. Should a return be granted, the purchase amount less shipping & handling fee and other applicable fees (restocking charge) will be deducted.