BA310 Digital - Motic Microscopes

BA310 Digital

$3,398


The demands placed on any routine microscope for daily work needs careful focus on every microscopic detail. The new BA310 series features a powerful adjustable light source to meet both delicate and detailed lighting requirements for all sample types while the fully featured Koehler illumination helps in highlighting even the weakest stained specimens.


          ModelBA310 Digital
          Observation tubeBinocular head, Siedentopf type with built-in digital camera
          Optical system Colour Corrected Infinity Optical System (CCIS®)
          Sensor typeCMOS
          Sensor size1/2"
          Capture resolution5MP
          Live display through USB2048x1536 pixels
          Data transferUSB 2.0
          Inclination 30° inclined, 360° rotating
          Interpupillary distance 55-75mm
          Diopter adjustment On both eyepieces, +/- 5 diopter
          Eyepieces Widefield N-WF10X/20mm with diopter adjustment
          Nose pieceReversed quintuple 
          Objective classificationCCIS EC Plan Achromat, DIN
          Objectives4X/0.10 (WD 15.9mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.5mm), 100X/1.25/S-Oil (WD 0.15mm)
          Objective mounting threadW 4/5" x 1/36" (RMS standard)
          Stand type Upright
          StageMechanical stage with built-in low position coaxial stage control with tension adjustment and 2-sampale holder
          Stage size175X140mm
          Travel range X&Y 76X50mm
          Condenser Focusable Abbe Condenser N.A. 0.90/1.25 with iris diaphragm and slot for contrast sliders
          DiaphragmIris diaphragm
          Focus mechanismCoaxial coarse and fine focusing system with tension adjustment
          Fine focus precision2 µm 
          Focusing stroke 20mm
          Upper limit stopUpper limit stop preset but adjustable
          Filter holderOn top of the illuminator with fixing cap
          Transmitted illumination LED Koehler illumination with intensity control
          SoftwareMotic Images Plus 3.0 for Windows, OSX and Linux
          TransformerInternal
          Power supply100-240V (CE)
          Accessories included Dust cover, power cord, allen key, immersion oil (5ml), thumb screw, calibration slide, USB cable, spare fuse, and cord hanger.
          Dimensions LxWxH400x220x458mm
          Net weight8.8kg
          Contrast techniques 
          Standard contrast technique Brightfield
          PolarizationOptional add-on
          Phase contrastOptional slider/turret
          DarkfieldOptional slider/turret

          Koehler Illumination - Setup & Alignment

          Know how to use the Koehler illumination properly in the BA310, BA310E, BA410 and BA410E Series.

          How to replace the PCB LED illumination of a BA210 and a BA310 LED

          Learn how easy it is to replace the PCB LED illumination of BA210 and a BA310 LED microscopes.

          Contrast Methods - Polarization Contrast in BA210, BA210E, BA310 & BA310E

          Discover how to setup the polarizing equipment in our BA210 and BA310 upright microscopes, and its Elite versions.

          Contrast Methods - Polarizing system

          Discover how to use the polarization contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.

          Contrast Methods - Simple Phase Contrast

          Discover how to use the Phase Contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.

          Contrast Methods - Turret Phase Contrast

          Discover how to perform the Phase Contrast method with the Turret Condenser solution, in our upright microscopes BA310, BA410 and its Elite versions.

          Contrast Methods - Darkfield with turret solution for BA310, BA310E & BA410E

          Discover how to perform the darkfield contrast method with the turret solution, in our BA series of upright microscopes BA310, BA310E and BA410E models.

          Contrast Methods - Darkfield with slider solution for BA series

          Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions.

          How to change the halogen bulb & LED module of a BA210, BA310, BA210E and BA310E

          Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA210, BA310, BA210E and BA310E microscopes.

          How to adjust the tension of the focusing system (ring). E.g. AE Series

          Learn how easy it is to adjust the tension of the focusing system of your Motic microscope.

          How to do the parfocality adjustment on an upright microscope

          Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.

          How to avoid repairs in your microscope

          Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.

          At Motic Instruments, we take pride in the quality of our products and our user experience. That's why we offer technical advice and full post-sale support to keep your Motic products in optimal condition and ensure your microscopy results are of the highest quality. All of our microscopes are covered by a 5 year warranty on mechanical components and 1 year warranty on electrical components. 

          All returns must be authorized by Motic Instruments in order to insure proper credit and must be requested within 15 days of purchase. All returns may be subject to a 25% restocking charge and any cancellations may be subject to a cancellation fee. For returns not due to Motic error, the customer is responsible for all transportation fees related to the returned product. Should a return be granted, the purchase amount less shipping & handling fee and other applicable fees (restocking charge) will be deducted.

          Downloads

          Videos

          Koehler Illumination - Setup & Alignment

          Know how to use the Koehler illumination properly in the BA310, BA310E, BA410 and BA410E Series.

          How to replace the PCB LED illumination of a BA210 and a BA310 LED

          Learn how easy it is to replace the PCB LED illumination of BA210 and a BA310 LED microscopes.

          Contrast Methods - Polarization Contrast in BA210, BA210E, BA310 & BA310E

          Discover how to setup the polarizing equipment in our BA210 and BA310 upright microscopes, and its Elite versions.

          Contrast Methods - Polarizing system

          Discover how to use the polarization contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.

          Contrast Methods - Simple Phase Contrast

          Discover how to use the Phase Contrast accessories in our BA210, BA310 and BA410 upright microscopes, including the Elite versions.

          Contrast Methods - Turret Phase Contrast

          Discover how to perform the Phase Contrast method with the Turret Condenser solution, in our upright microscopes BA310, BA410 and its Elite versions.

          Contrast Methods - Darkfield with turret solution for BA310, BA310E & BA410E

          Discover how to perform the darkfield contrast method with the turret solution, in our BA series of upright microscopes BA310, BA310E and BA410E models.

          Contrast Methods - Darkfield with slider solution for BA series

          Discover how to perform the darkfield contrast method with the slider solution, in our BA series of upright microscopes BA210, BA310, BA410 and its Elite versions.

          How to change the halogen bulb & LED module of a BA210, BA310, BA210E and BA310E

          Learn how easy it is to replace the halogen bulb and the LED module and how to interchange the halogen/LED illumination in your Motic BA210, BA310, BA210E and BA310E microscopes.

          How to adjust the tension of the focusing system (ring). E.g. AE Series

          Learn how easy it is to adjust the tension of the focusing system of your Motic microscope.

          How to do the parfocality adjustment on an upright microscope

          Wondering what a microscope's parfocality is and how to do it when using an upright microscope? In this video, we will explain it and show you by following some easy steps.

          How to avoid repairs in your microscope

          Do you want to know how to keep your microscope in its best condition? In this video, we will give you some basic tricks to carry out; before, during, and after its use and thus avoid possible repairs.

          Warranty

          At Motic Instruments, we take pride in the quality of our products and our user experience. That's why we offer technical advice and full post-sale support to keep your Motic products in optimal condition and ensure your microscopy results are of the highest quality. All of our microscopes are covered by a 5 year warranty on mechanical components and 1 year warranty on electrical components. 

          Return Policy

          All returns must be authorized by Motic Instruments in order to insure proper credit and must be requested within 15 days of purchase. All returns may be subject to a 25% restocking charge and any cancellations may be subject to a cancellation fee. For returns not due to Motic error, the customer is responsible for all transportation fees related to the returned product. Should a return be granted, the purchase amount less shipping & handling fee and other applicable fees (restocking charge) will be deducted.